| :: analyzers :: (sort by measurement) |
technical information |
= Discontinued or Obsolete
- Opacity
Opacity is the degree to which the transmission of light is reduced or the degree to which visibility of a background, as viewed through the diameter of a plume, is reduced. A transmissometer (or opacity analyzer) measures the amount of light that is lost to scattering or absorption in the emission's effluent. It is expressed in percentage usually, but sometimes in Ringelmann numbers.
OPM2000
OPM2000A
OPM2000R
OPM2001
- Chemiluminescence
The method of detection where a chemical reaction generating light is used to measure the amount of Oxides of Nitrogen (NOx) found typically in a combustion process flue gas.
951
951A
951C
951E
955
958
NGA2000 CLD Module
NGA2000 WCLD Module
- Paramagnetic
This detection method is based on the effect of magnetic lines of flux on oxygen molecules.
755/G
755A
755EX
755R
OXYNOS 100
NGA2000 PMD
NGA2000 PMD2
NGA2000 FR-PMD
TO2
- NDIR (Non-Dispersive InfraRed)
By passing infrared energy through a cavity to a detector the measurement is based on the difference in response of the detector with the gas-of-interest present in the cavity versus its response with no gas of interest in the cavity.
5100/A (in-situ CO2 NDIR measurement)
815
864
865
865EX
867
868
870
880
880A
NGA2000 NDIR Module
- Flame Ionization
Flame ionization is the method of detection where the total amount of carbon atoms (THC-total hydrocarbons) in a gas stream is determined by a measuring a minute current proportional to the amount of THC present in the combustion chamber.
400
400A
402
402RS
404
FID
FID2
MCFID
TFID
- Thermal Conductivity
Gases are measured by their ability to affect the transfer of heat away from the detecting heat source.
7C
7D
CAT7
HYDROS 100
- Polaragraphic
Oxygen concentration derived from a proportional current flow between the anode and cathode in an electrochemical cell.
7001
7001D
7002D
7003D
7003M
OXYNOS 100
ROX/GP
ROX/GT
- Multi-Component
These units combine measurement "benches" utilizing several different principles of analysis, i.e. an NIDR, Thermal Conductivity, & an Oxygen cell all in the same unit.
NGA2000/MLT
- MLT1
- MLT2
- MLT3
- MLT4
- Platforms
- Power Supplies
- I/O cards
CAT100
CAT200
BINOS
- Transflectance (UV)
These analyzers use spectrally selective mirrors to isolate Ultraviolet spectral pass-bands prior to actual detection.
890 SO2
890 Cl2
- Trace Moisture
This measurement is based on the absorption and electrolysis of moisture in and electrolytic cell.
340
- Zirconium Oxide
This method of analysis combines the ionization of O2 and a catalytic reaction between two platinum electrodes to produce a millivolt signal proportional to the concentration of O2 in the sample.
132
200
218
225
240
3081
4081
5081
Oxymitter 4000
Oxymitter 5000
OXT4A/C
OXT5A/C
World Class (Universal)
World Class 3000
- Controllers, Boiler
Multi loop controllers typically used to control the fuel/air ratio in combustion processes.
1500
1500A
EC3
TC200
- Etalon analyzers
The means of differential gas absorption measurement where spectral correlation is removed by the use of an electro-optic modulator.
9100
9200
- Chart Recorders
- Fan/Damper Drives
All Hagan/Rosemount models
|
|