:: analyzers ::  (sort by measurement)   technical information  

        = Discontinued or Obsolete

- Opacity
    Opacity is the degree to which the transmission of light is reduced or the degree to which visibility of a background, as viewed through the diameter of a plume, is reduced.  A transmissometer (or opacity analyzer) measures the amount of light that is lost to scattering or absorption in the emission's effluent.  It is expressed in percentage usually, but sometimes in Ringelmann numbers.

     OPM2000 
     OPM2000A 
     OPM2000R 
     OPM2001

- Chemiluminescence
    The method of detection where a chemical reaction generating light is used to measure the amount of Oxides of Nitrogen (NOx) found typically in a combustion process flue gas.

     951 
     951A
     951C
     951E 
     955 
     958 
     NGA2000 CLD Module
     NGA2000 WCLD Module
- Paramagnetic
    This detection method is based on the effect of magnetic lines of flux on oxygen molecules.

     755/G
     755A
     755EX
     755R
    OXYNOS 100
     NGA2000 PMD 
     NGA2000 PMD2
     NGA2000 FR-PMD 
     TO2 
- NDIR (Non-Dispersive InfraRed)
    By passing infrared energy through a cavity to a detector the measurement is based on the difference in response of the detector with the gas-of-interest present in the cavity versus its response with no gas of interest in the cavity.

     5100/A (in-situ CO2 NDIR measurement) 
     815
     864 
     865 
     865EX 
     867 
     868 
     870 
     880 
     880A
     NGA2000 NDIR Module 
- Flame Ionization
    Flame ionization is the method of detection where the total amount of carbon atoms (THC-total hydrocarbons) in a gas stream is determined by a measuring a minute current proportional to the amount of THC present in the combustion chamber.

     400 
     400A
     402 
     402RS 
     404 
     FID 
     FID2
     MCFID 
     TFID
- Thermal Conductivity
    Gases are measured by their ability to affect the transfer of heat away from the detecting heat source.

     7C 
     7D 
     CAT7 
     HYDROS 100
- Polaragraphic
    Oxygen concentration derived from a proportional current flow between the anode and cathode in an electrochemical cell.

     7001 
     7001D 
     7002D 
     7003D 
     7003M 
     OXYNOS 100
     ROX/GP
     ROX/GT
- Multi-Component
    These units combine measurement "benches" utilizing several different principles of analysis, i.e. an NIDR, Thermal Conductivity, & an Oxygen cell all in the same unit.

     NGA2000/MLT
    • MLT1
    • MLT2
    • MLT3
    • MLT4
    • Platforms
    • Power Supplies
    • I/O cards
     CAT100
     CAT200
     BINOS

- Transflectance (UV)

    These analyzers use spectrally selective mirrors to isolate Ultraviolet spectral pass-bands prior to actual detection.

     890  SO2
     890  Cl2
- Trace Moisture

    This measurement is based on the absorption and electrolysis of moisture in and electrolytic cell.

     340 
- Zirconium Oxide
    This method of analysis combines the ionization of O2 and a catalytic reaction between two platinum electrodes to produce a millivolt signal proportional to the concentration of O2 in the sample.

     132 
     200 
     218 
     225 
     240
     3081 
     4081 
     5081
     Oxymitter 4000
     Oxymitter 5000
     OXT4A/C
     OXT5A/C
     World Class (Universal)
     World Class 3000
- Controllers, Boiler
    Multi loop controllers typically used to control the fuel/air ratio in combustion processes.

     1500 
     1500A
     EC3
     TC200 
- Etalon analyzers
    The means of differential gas absorption measurement where spectral correlation is removed by the use of an electro-optic modulator.

     9100 
     9200 
- Chart Recorders
     All Chessell models
- Fan/Damper Drives
     All Hagan/Rosemount models