- Opacity Opacity is the degree to which the transmission of light is reduced or the degree to which visibility of a background, as viewed through the diameter of a plume, is reduced. A transmissometer (or opacity analyzer) measures the amount of light that is lost to scattering or absorption in the emission's effluent. It is expressed in percentage usually, but sometimes in Ringelmann numbers.
Rosemount OPM2000 (still supported with parts & service by RIGAS) Rosemount OPM2000A (still supported with parts & service by RIGAS) Rosemount OPM2000R (still supported with parts & service by RIGAS) Rosemount OPM2001 (still supported with parts & service by RIGAS)
- Chemiluminescence The method of detection where a chemical reaction generating light is used to measure the amount of Oxides of Nitrogen (NOx) found typically in a combustion process flue gas.
Rosemount / Beckman 951 Rosemount / Beckman 951A Rosemount 951C Rosemount 951E Rosemount / Beckman 955 Rosemount / Beckman 958 Rosemount NGA2000 CLD Module Rosemount NGA2000 WCLD Module - Paramagnetic This detection method is based on the effect of magnetic lines of flux on oxygen molecules. The oxygen molecules tend to pool around the high intensity flux lines.
Rosemount / Beckman 755/G Rosemount / Beckman 755A Rosemount / Beckman 755EX Rosemount 755R OXYNOS 100 Rosemount NGA2000 PMD Rosemount NGA2000 PMD2 Rosemount NGA2000 FR-PMD
- Chemical cell, Trace Oxygen Rosemount NGA-TO2
- NDIR (Non-Dispersive InfraRed)
This method of detection is based on the Luft detector; by passing infrared energy through two cells (reference & measuring) to a detector (the Luft detector) the difference in IR energy is determined; the higher the difference, the higher the concentration of the gas-of-interest. The detector is non-linear.
Rosemount 5100/A (in-situ CO2 NDIR measurement) Beckman 815 Beckman 864 Beckman 865 Beckman 865EX Beckman 867 Beckman 868 Rosemount / Beckman 870 Rosemount / Beckman 880 Rosemount / Beckman 880A Rosemount NGA2000 NDIR Module - Flame Ionization Flame ionization is the method of detection where the total amount of carbon atoms (THC stands for total hydrocarbons) in a gas stream is determined by a measuring a minute current proportional to the amount of THC present in the combustion chamber. A hydrogen flame (from either pure H2 or a 40/60 mix of H2/He) liberates the carbon ions; the ions create a minute current flow to a collector plate; the current is measured and converted to (usually) a ppm concentration value.
Beckman 400 Rosemount 400A Beckman 402 Beckman 402RS Beckman 404 Rosemount NGA-FID1 Rosemount NGA-FID2 Rosemount NGA-MCFID Rosemount NGA-TFID (thermal FID) - Thermal Conductivity Gases are measured by their ability to affect the transfer of heat away from the detecting heat source.
7C 7D CAT7 HYDROS 100 - Polaragraphic Oxygen concentration derived from a proportional current flow between the anode and cathode in an electrochemical cell.
7001 7001D 7002D 7003D 7003M OXYNOS 100 ROX/GP ROX/GT - Multi-Component These units combine measurement "benches" utilizing several different principles of analysis (i.e., an NDIR, Thermal Conductivity, & an Oxygen cell can all be contained in the same unit).
NGA2000/MLT
- MLT1
- MLT2
- MLT3
- MLT4
- Platforms
- Power Supplies
- I/O cards
CAT100 CAT200 BINOS
- Transflectance (UV)
These analyzers use spectrally selective mirrors to isolate Ultraviolet spectral pass-bands prior to actual detection.
890 SO2 890 Cl2 - Trace Moisture
This measurement is based on the absorption and electrolysis of moisture in and electrolytic cell.
340 - Zirconium Oxide This method of analysis combines the ionization of O2 and a catalytic reaction between two platinum electrodes to produce a millivolt signal proportional to the concentration of O2 in the sample.
132 200 218 225 240 3081 4081 5081 Oxymitter 4000 Oxymitter 5000 OXT4A/C OXT5A/C World Class (Universal) World Class 3000 - Controllers, Boiler Multi loop controllers typically used to control the fuel/air ratio in combustion processes.
1500 1500A EC3 TC200 - Etalon analyzers The means of differential gas absorption measurement where spectral correlation is removed by the use of an electro-optic modulator.
9100 9200 - Chart Recorders - Fan/Damper Drives All Hagan/Rosemount models
- Chemiluminescence The method of detection where a chemical reaction generating light is used to measure the amount of Oxides of Nitrogen (NOx) found typically in a combustion process flue gas.
Rosemount / Beckman 951 Rosemount / Beckman 951A Rosemount 951C Rosemount 951E Rosemount / Beckman 955 Rosemount / Beckman 958 Rosemount NGA2000 CLD Module Rosemount NGA2000 WCLD Module - Paramagnetic This detection method is based on the effect of magnetic lines of flux on oxygen molecules.
Rosemount / Beckman 755/G Rosemount / Beckman 755A Rosemount / Beckman 755EX Rosemount 755R OXYNOS 100 Rosemount NGA2000 PMD Rosemount NGA2000 PMD2 Rosemount NGA2000 FR-PMD
- Chemical cell, Trace Oxygen Rosemount NGA-TO2
- NDIR (Non-Dispersive InfraRed)
By passing infrared energy through a cavity to a detector the measurement is based on the difference in response of the detector with the gas-of-interest present in the cavity versus its response with no gas of interest in the cavity.
Rosemount 5100/A (in-situ CO2 NDIR measurement) Beckman 815 Beckman 864 Beckman 865 Beckman 865EX Beckman 867 Beckman 868 Rosemount / Beckman 870 Rosemount / Beckman 880 Rosemount / Beckman 880A Rosemount NGA2000 NDIR Module - Flame Ionization Flame ionization is the method of detection where the total amount of carbon atoms (THC-total hydrocarbons) in a gas stream is determined by a measuring a minute current proportional to the amount of THC present in the combustion chamber.
Beckman 400 Rosemount 400A Beckman 402 Beckman 402RS Beckman 404 Rosemount NGA-FID1 Rosemount NGA-FID2 Rosemount NGA-MCFID Rosemount NGA-TFID (thermal FID) - Thermal Conductivity Gases are measured by their ability to affect the transfer of heat away from the detecting heat source.
7C 7D CAT7 HYDROS 100 - Polaragraphic Oxygen concentration derived from a proportional current flow between the anode and cathode in an electrochemical cell.
7001 7001D 7002D 7003D 7003M OXYNOS 100 ROX/GP ROX/GT - Multi-Component These units combine measurement "benches" utilizing several different principles of analysis, i.e. an NIDR, Thermal Conductivity, & an Oxygen cell all in the same unit.
NGA2000/MLT
- MLT1
- MLT2
- MLT3
- MLT4
- Platforms
- Power Supplies
- I/O cards
CAT100 CAT200 BINOS
- Transflectance (UV)
These analyzers use spectrally selective mirrors to isolate Ultraviolet spectral pass-bands prior to actual detection.
890 SO2 890 Cl2 - Trace Moisture
This measurement is based on the absorption and electrolysis of moisture in and electrolytic cell.
340 - Zirconium Oxide This method of analysis combines the ionization of O2 and a catalytic reaction between two platinum electrodes to produce a millivolt signal proportional to the concentration of O2 in the sample.
132 200 218 225 240 3081 4081 5081 Oxymitter 4000 Oxymitter 5000 OXT4A/C OXT5A/C World Class (Universal) World Class 3000 - Controllers, Boiler Multi loop controllers typically used to control the fuel/air ratio in combustion processes.
1500 1500A EC3 TC200 - Etalon analyzers The means of differential gas absorption measurement where spectral correlation is removed by the use of an electro-optic modulator.
9100 9200 - Chart Recorders - Fan/Damper Drives All Hagan/Rosemount models
|
|